<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2d1 20170631//EN" "JATS-journalpublishing1.dtd">
<article xlink="http://www.w3.org/1999/xlink" dtd-version="1.0"><Article><Journal><PublisherName>dawnmed</PublisherName><JournalTitle>DawnMed Journal of Medical Science</JournalTitle><PISSN>I</PISSN><EISSN>S</EISSN><Volume-Issue>Volume 2, Issue 4</Volume-Issue><IssueTopic>Multidisciplinary</IssueTopic><IssueLanguage>English</IssueLanguage><Season>2026</Season><SpecialIssue>N</SpecialIssue><SupplementaryIssue>N</SupplementaryIssue><IssueOA>Y</IssueOA><PubDate><Year>2026</Year><Month>10</Month><Day>8</Day></PubDate><ArticleType>Ophthalmology</ArticleType><ArticleTitle>Visual and refractive outcomes, spectacle independence and patient satisfaction after extended depth-of-focus intraocular lens implantation: a retrospective single-centre case series of 45 eyes</ArticleTitle><SubTitle/><ArticleLanguage>English</ArticleLanguage><ArticleOA>Y</ArticleOA><FirstPage>14</FirstPage><LastPage>21</LastPage><AuthorList><Author><FirstName>Sana</FirstName><LastName>Saeed¹*</LastName><AuthorLanguage>English</AuthorLanguage><Affiliation/><CorrespondingAuthor>N</CorrespondingAuthor><ORCID/><FirstName>Adel</FirstName><LastName>Rushood¹</LastName><AuthorLanguage>English</AuthorLanguage><Affiliation/><CorrespondingAuthor>Y</CorrespondingAuthor><ORCID/><FirstName>Adi Al</FirstName><LastName>Owaifeer¹</LastName><AuthorLanguage>English</AuthorLanguage><Affiliation/><CorrespondingAuthor>Y</CorrespondingAuthor><ORCID/></Author></AuthorList><DOI/><Abstract>Purpose: To describe uncorrected distance visual acuity over the first 6 months, and postoperative intermediate and near acuity, refraction, spectacle use, photic phenomena and satisfaction, after cataract surgery with an extended depth-of-focus (EDOF) intraocular lens (IOL).Setting: Private eye centre, Dammam, Saudi Arabia.Design: Retrospective single-centre case series.Methods: Forty-five eyes of 25 patients (mean age 53.4 ± 9.6 years) underwent phacoemulsification with implantation of one of two EDOF IOLs (Bi-Flex ELON, Medicontur; Synthesis+, Cutting Edge) between August 2022 and September 2023. Uncorrected distance visual acuity (UDVA) was recorded before surgery and at 2 weeks and 1, 3 and 6 months. Intermediate and near acuity, binocular acuity, refraction, satisfaction, spectacle use and photic phenomena were recorded at one further postoperative assessment. Inferential analyses used the first operated eye of each patient (n = 25); results for all 45 eyes are descriptive.Results: In first eyes, mean UDVA improved from 0.45 ± 0.23 to 0.07 ± 0.09 logMAR (change −0.38, 95% confidence interval [CI] −0.47 to −0.28; p &lt; 0.001), and 85% of this change had occurred by 1 month. At 6 months, 73% of all eyes had UDVA of 20/25 or better. Uncorrected intermediate and near acuity were 20/25 or better in 67% and 76% of eyes (84% and 89% with distance correction). Postoperative spherical equivalent was −0.30 ± 0.72 D and was within ±0.50 D of emmetropia in 58% of eyes. Twenty-two of 25 patients (88%) reported needing no spectacles for daily activities, and 24 (96%) were fully or fairly satisfied with distance vision. Eleven patients (44%) reported at least one photic phenomenon, most often halos (28%). The eight eyes with previous radial keratotomy, vitrectomy or amblyopia had a mean 6-month UDVA of 0.23 logMAR, compared with 0.06 logMAR in the other 37 eyes.Conclusions: After EDOF IOL implantation, about three quarters of eyes reached uncorrected acuity of 20/25 or better at distance and near, and most patients reported not needing spectacles. Photic phenomena were reported by 44% of patients. Without a control group, these outcomes cannot be attributed to the lens designs.</Abstract><AbstractLanguage>English</AbstractLanguage><Keywords>cataract extraction; extended depth of focus; intraocular lens; patient satisfaction; dysphotopsia; spectacle independence.</Keywords><URLs><Abstract>https://dawnmed.com.sa/abstract?id=36</Abstract></URLs><References><ReferencesarticleTitle>References</ReferencesarticleTitle><ReferencesfirstPage>16</ReferencesfirstPage><ReferenceslastPage>19</ReferenceslastPage><References>MacRae S, Holladay JT, Glasser A, et al. Special report: American Academy of Ophthalmology Task Force consensus statement for extended depth of focus intraocular lenses. Ophthalmology. 2017;124(1):139-141. doi:10.1016/j.ophtha.2016.09.039Khandelwal SS, Jun JJ, Mak S, Booth MS, Shekelle PG. Effectiveness of multifocal and monofocal intraocular lenses for cataract surgery and lens replacement: a systematic review and meta-analysis. Graefes Arch Clin Exp Ophthalmol. 2019;257(5):863-875. doi:10.1007/s00417-018-04218-6Cao K, Friedman DS, Jin S, et al. Multifocal versus monofocal intraocular lenses for age-related cataract patients: a system review and meta-analysis based on randomized controlled trials. Surv Ophthalmol. 2019;64(5):647-658. doi:10.1016/j.survophthal.2019.02.012Pedrotti E, Bruni E, Bonacci E, Badalamenti R, Mastropasqua R, Marchini G. Comparative analysis of the clinical outcomes with a monofocal and an extended range of vision intraocular lens. J Refract Surg. 2016;32(7):436-442. doi:10.3928/1081597X-20160428-06Cochener B; Concerto Study Group. Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study. J Cataract Refract Surg. 2016;42(9):1268-1275. doi:10.1016/j.jcrs.2016.06.033Braga-Mele R, Chang D, Dewey S, et al.; ASCRS Cataract Clinical Committee. Multifocal intraocular lenses: relative indications and contraindications for implantation. J Cataract Refract Surg. 2014;40(2):313-322. doi:10.1016/j.jcrs.2013.12.011Woodward MA, Randleman JB, Stulting RD. Dissatisfaction after multifocal intraocular lens implantation. J Cataract Refract Surg. 2009;35(6):992-997. doi:10.1016/j.jcrs.2009.01.031Son HS, Kim SH, Auffarth GU, Choi CY. Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population. BMC Ophthalmol. 2019;19(1):187. doi:10.1186/s12886-019-1193-zGundersen KG, Makari S, Ostenstad S, Potvin R. Retreatments after multifocal intraocular lens implantation: an analysis. Clin Ophthalmol. 2016;10:365-371. doi:10.2147/OPTH.S100840Kohnen T, Band;ouml;hm M, Hemkeppler E, et al. Visual performance of an extended depth of focus intraocular lens for treatment selection. Eye (Lond). 2019;33(10):1556-1563. doi:10.1038/s41433-019-0443-x</References></References></Journal></Article></article>
